TM.G7SW.117
ALREADY ON HOME SWITCH: If a homing sequence is initiated and the home switch is already activated, the
drive will “back off” of the home switch and then proceed with the normal homing sequence. If the homing type is
either “Home Positive with Backup” or “Home Negative with Backup,” an abbreviated homing routine is run instead.
Figure 18: Home Negative, starting on home switch (P2-01 = 0)
Figure 19: Home Negative with Backup, starting on home switch (P2-01 = 1)
Digital
Inputs
Motor
Speed
Digital
Outputs
Run Cmd
Home Cmd
During Move
Move Complete
Back Off Of
Home Switch
In Position
Window
(P1-08)
0 Hz
Home Switch
Homing Needed
At Home
Homing Complete
(-)P2-02
(+)P2-03
Move To
Home
Digital
Inputs
Motor
Speed
Digital
Outputs
Run Cmd
Home Cmd
During Move
Move Complete
In Position
Window
(P1-08)
0 Hz
Home Switch
Homing Needed
At Home
Homing Complete
(+)P2-03
(-)P2-04
Back Off Of
Home Switch