Yaskawa AC Drive - A1000 Motion Control Custom User Manual

Page 13

Advertising
background image

4 Related Parameters and Functions

YASKAWA TM.A1000SW.117 Motion Control Custom Software Supplement

13

Table 4 Additional Group Text

Table 5 Additional Function Text

Table 6 Monitor Function Text

Table 7 Monitors

L3-04

(492h)

Stall Prevention Selection
StallP Decel Sel

0: Disabled. Deceleration at the active
deceleration rate. An ov fault may occur.
1: General purpose. Deceleration is paused
when the DC bus voltage exceeds
the Stall Prevention level.
2: Intelligent. Decelerate as fast as
possible while avoiding ov faults.
3: Stall Prevention with braking resistor.
Stall Prevention during deceleration is
enabled in coordination with dynamic
braking.
4: Overexcitation Deceleration.
Decelerates while increasing the motor
flux.
5: Overexcitation Deceleration 2. Adjust
the deceleration rate according to the DC
bus voltage.
Note: Setting 3 is not available in models
CIMR-A□4A0930 and 4A1200.

Default: 0
Range: 0 to 2

No

<1> Setting range value is dependent on parameter C1-10, Accel/Decel Time Setting Units. The settings range becomes 0.00 to 600.00 seconds

when C1-10=0 (units of seconds).

<2> Default setting is determined by parameter A1-02, Control Method Selection.

<3> F1-32 is normally only visible when motor 2 is selected. F1-32 is now visible in the correct modes regardless of the motor 2 switch setting.

Function Group

Group Name

Digital Operator Display

P

Motion Control
Motion Control

Function No.

Group Name

Digital Operator Display

P1

Motion Setup
Motion Setup

P2

Homing Setup
Homing Setup

P3

Advanced Motion Setup
Adv Motion Setup

P4

Preset Position Setup
Preset Pos Setup

Monitor No.

Group Name

Digital Operator Display

U7

Motion Control
Motion Control

No.

(Addr.

Hex)

Parameter Name

Digital Operator Display

Description

Analog Output

Scaling

Unit

Control Mode

Access Level

U7-02

(0661h)

Distance From Home (Fine)

Dist From Home f

Distance from home (+ home offset) for absolute
applications, or distance from start of previous move
for relative applications. Displayed with fine
resolution (0.01 units).

N/A

0.01 Unit

<1>

No.

(Addr.

Hex)

Parameter Name

Digital Operator Display

Description

Values

Change

During

Run

Control Mode

Access Level

V/f

V/f

All Modes

All Modes

Advertising