5 Function Description

YASKAWA TM.A1000SW.117 Motion Control Custom Software Supplement

21

The position reference is scaled as follows: Commanded Position (in encoder counts) = Frequency Reference × P1-09.
Move velocity is determined by parameter d1-09, and accel and decel rates are determined by parameters C1-01 and C1-
02. For example:
If P1-09 = 4096 counts/unit, and the frequency reference over the option PCB is 15.00 Hz, this would result in a move
that is exactly 61440 encoder counts (4096 × 15.00 = 61440). The option frequency reference channel returns to normal
operation as an actual frequency reference when motion control is disabled.

1. The position reference is scaled as follows:

Commanded Position (in encoder counts) = Frequency Reference × P1-09

2. Move velocity is determined by parameter d1-09, and accel and decel rates are determined by parameters C1-01 and

C1-02.
For example: If P1-09 = 4096 counts/unit, and the frequency reference over the option PCB is 15.00 Hz, this would
result in a move that is exactly 61440 encoder counts (4096 × 15.00 = 61440).

When motion control is disabled, the option frequency reference channel returns to normal operation as an actual
frequency reference.

Table 15 Profile Selection Information

Distance

Select

D

<1>

Distance

Select

C

<1>

Distance

Select

B

<1>

<1> Programmable using the digital input parameters H1-01 to H1-10.

<2> When P1-02=1, the actual commanded destination is calculated as follows:

Destination=Memobus register 6D0H × P1-09/100

<3> Actual destination (in encoder quadrature counts) is calculated as follows when b1-01= 3:

<4> When motion control is disabled, the Option PCB frequency reference register returns to its normal function.

Distance

Select

A

<1>

Parameter

P1-02

Setting

Position Reference Source Accel/Decel

Parameters

Max Speed

Used

Open

Open

Open

Open

0

Parameter P4-01

C1-01 and

C1-02

d1-09

1

Memobus Address

06D1h

100=1.00 Units

<2>

Memobus

Address

06D0h

2

Option PCB Frequency

Reference Register

<3>

<4>

(in XXX.XX Units)

d1-09

3

Memobus Address

06D0h (low word) and

06D1h (high word)

In quadrature encoder counts.

Open

Open

Open

Closed

N/A

P4-02

C1-03 & C1-04

d1-10

Open

Open

Closed

Open

N/A

P4-03

C1-05 & C1-06

d1-11

Open

Open

Closed

Closed

N/A

P4-04

C1-07 & C1-08

d1-12

Open

Closed

Open

Open

N/A

P4-05

C1-01 & C1-02

d1-13

Open

Closed

Open

Closed

N/A

P4-06

C1-03 & C1-04

d1-14

Open

Closed

Closed

Open

N/A

P4-07

C1-05 & C1-06

d1-15

Open

Closed

Closed

Closed

N/A

P4-08

C1-07 & C1-08

d1-16

Closed

Open

Open

Open

N/A

P4-09

C1-01 & C1-02

d1-09

Closed

Open

Open

Closed

N/A

P4-10

C1-03 & C1-04

d1-10

Closed

Open

Closed

Open

N/A

P4-11

C1-05 & C1-06

d1-11

Closed

Open

Closed

Closed

N/A

P4-12

C1-07 & C1-08

d1-12

Closed

Closed

Open

Open

N/A

P4-13

C1-01 & C1-02

d1-13

Closed

Closed

Open

Closed

N/A

P4-14

C1-03 & C1-04

d1-14

Closed

Closed

Closed

Open

N/A

P4-15

C1-05 & C1-06

d1-15

Closed

Closed

Closed

Closed

N/A

P4-16

C1-07 & C1-08

d1-16

Destination =

Frequency Reference (hi-speed rgister)

100

P1-10

X