Figure 20 Home Negative with Backup Starting on Home Switch (P2-01=1)

Homing When Reverse Operation is Disabled

Homing can be affected whenever reverse operation is prohibited (b1-04 = 1). The only homing routines that could be
effectively used in under these conditions would be home forward and home forward with marker. If any other homing
type is selected when reverse is disabled, the homing routine will never complete. Normally, when the home switch is
activated at the beginning of a homing routine, the drive would back-up off of the home switch. Since backing up is not
allowed, the drive will move forward until the next leading edge of the home switch is encountered.

Figure 21

represents

a home positive timing chart, reverse prohibited, starting on home switch with relative or relative with memory motion
type.

If motion type is Relative or Relative w/memory (P1-01 = 3 or 4) when the rising edge of the home switch is encountered,
the drive simply ramps to stop and does not attempt to move to home, but instead simply records the home position.

Figure 21

Figure 21 Home Positive Timing Chart, Reverse prohibit, Starting on home switch, Relative or relative with memory motion

type.

(P2-01=2, b1-04=1)

Digital
Inputs

Motor

Speed

Digital

Outputs

Run Cmd

Home Cmd

During Move

Move Complete

In Position

Window

(P1-08)

0 Hz

Home Switch

Homing Needed

At Home

Homing Compl.

(+)P2-03

(-)P2-04

Back Off Of

Home Switch

Digital
Inputs

Motor

Speed

Digital

Outputs

Run Cmd

Home Cmd

C1-07

In Position

Window

(P1-08)

0 Hz

Home Switch

C1-08

(+)P2-02

During Move

Move Complete

Homing Needed

At Home

Homing Compl.