Amprobe PQ55A Power-Analyzer User Manual

Page 20

Advertising
background image

Press the “POWER” key to switch between the measurement values of
Phase L1, Phase L2 and Phase 3 and the total value. The respectively dis-
played value can be assigned by means of the suffix 1, 2, 3, or t (5.2.).

The following additional measurement values can be selected subsequently and
indicated on the additional display (5.13):

To display the mains frequency, press the “Hz“ key (12).

To display the phase angle, press the

0

key (11).

To display the power factor, press the “PF” key (10).

If required, press the “I4” key (13) to display the protective earth current

Individual measurements may be saved using the “M/MEMORY” key (19)

To measure the energy values, press the ”ENERGY“ key (22).

When this measurement type is selected, the automatic-power-off function of

the instrument is deactivated.

The following values are displayed.

Display Measurement type energy
In the lower part, the starting time of the measurement is displayed in the
“STAR” line (5.43). Below, the current date and time are displayed during the
measurement. I.e. the energy values are permanently calculated during running
display.
In the upper part of the display, the total values for the active power (5.4), the
idle power (5.7), the apparent power (5.21), and the power factor (5.13) are dis-
played (to be recognised by the suffix “t”) .

The measurement is terminated when pressing the key (18).

The [HOLD] symbol is displayed on the screen and the final calculation time
appears in the “STOP” line (5.41).

The instrument returns to normal measurement when pressing
the “ ” key (16a).

The measurement values for the energy measurement cannot be saved.

20