002a verify failed – Avago Technologies 3ware 9650SE-12ML (Channel) User Manual

Page 290

Advertising
background image

Troubleshooting

278

3ware SAS/SATA RAID Software User Guide, Version 9.5.1

See Also

For information on scheduling a verify process, see “Scheduling Background
Tasks” on page 173.
For information on verification of a unit, see “About
Verification” on page 162
.

002A Verify failed

Event Type

Error

Cause

Verification of a unit has terminated with an error. For each RAID level being
verified, this may mean:

•

Single and Spare.

A single drive returned an error, possibly because of a

media defect.

•

RAID 0.

A single drive returned an error, possibly because of a media

defect.

•

RAID 1 and 10.

One side of the mirror does not equal the other side.

•

RAID 5, 6, and 50.

The parity data does not equal the user data.

For any RAID type, the most likely cause of the error is a grown defect in the
drive. For out-of-synchronization mirrors or parity, the error could be caused
by improper shutdown of the unit. This possibility applies to RAID 1, 5, 6, 10,
and 50.

Action

When a verify fails, redundant units will automatically resynchronize user
data through a background initialization. The initialize will not erase user
data, but will recalculate and rewrite user parity data.

If the unit was non-redundant, any data in the error location is lost. (However,
the error could be in a part of the drive that did not contain data.) A unit file
system check is recommended.

Under Windows, right-click on your drive icon and choose

Properties>

Tools> Check Now

.

Under Linux or FreeBSD use

fsck /dev/sda1

. If you have more than one

SATA device, substitute the correct drive letter and partition number, such as
sdb2, for sda1.

The resynchronization of data that takes place during a background
initialization can slow down access to the unit. Once initialization has begun,
it cannot be canceled. You can pause it, however, by scheduling it to take

Advertising