Avago Technologies 3ware 9650SE-12ML (Channel) User Manual

Page 327

Advertising
background image

www.3ware.com

315

•

Background rebuild rate

. The rate at which a particular controller

initializes, rebuilds, and verifies redundant units (RAID 1, RAID 5,
RAID 6, RAID 10, RAID 50).

•

Boot volume size.

The size to be assigned to volume 0 when creating a

unit through 3BM or CLI on a PC machine. Note that the resulting
volume does not have to be used as a boot volume. However, if the
operating system is installed on the unit, it is installed in volume 0.

•

Carve size.

The size over which a unit will be divided into volumes, if

auto-carving is enabled.

•

CLI

. Command Line Interface. The 3ware CLI is a text program, rather

than a GUI (graphical user interface). It has the same functionality as
3DM, and can be used to view, maintain, and manage 3ware controllers,
disks, and units.

•

Configuration

. The RAID level set for a unit.

•

Controller.

The physical card from 3ware that you insert into a computer

system and connect to your disk drives or enclosure. The controller
contains firmware that provides RAID functionality. 3ware makes a
number of different models of SATA RAID controllers. (See “System
Requirements” on page 2
.)

•

Controller ID number.

Unique number assigned to every 3ware

controller in a system, starting with zero.

•

Create an array

. The process of selecting individual disk drives and

selecting a RAID level. The array will appear to the operating system as a
single unit. Overwrites any existing unit configuration data on the drives.
Note that in 3ware software tools, arrays are referred to as units.

•

DCB.

Disk configuration block. This is 3ware proprietary RAID table

information that is written to disk drives that are in a RAID unit, single
disk, or spare. The DCB includes information on the unit type, unit
members, RAID level, and other important RAID information.

•

Delete an array.

Deleting an array (or unit) is the process of returning the

drives in a unit to individual drives. This erases the DCB information
from the drives and deletes any data that was on them. When a unit is
deleted from a controller, it is sometimes referred to as being “destroyed.”
If you want to remove a unit without deleting the data on it, do not delete
it; instead use the Remove feature in 3DM, and then physically remove
the drives.

•

Destroying

. Same as deleting a unit.

•

Degraded unit.

A redundant unit that contains a drive that has failed.

•

Disk roaming.

When moving a unit from one controller to another, refers

to putting disks back in a different order than they initially occupied,
without harm to the data.

Advertising