0036 verify fixed data/parity mismatch, 0037 so-dimm not compatible, 0038 so-dimm not detected – Avago Technologies 3ware 9650SE-12ML (Channel) User Manual

Page 296

Advertising
background image

Troubleshooting

284

3ware SAS/SATA RAID Software User Guide, Version 9.5.1

0036 Verify fixed data/parity mismatch

Event Type

Warning

Cause

A verify error was found and fixed by the 3ware RAID controller.

Some examples of errors that can be fixed include:

A parity inconsistency for a RAID 5 or RAID 50 unit.

A data mismatch for a RAID 1 or RAID 10 unit.

Action

None required.

0037 SO-DIMM not compatible

Event Type

Error

Cause

There is incompatible SO-DIMM memory connected to the 9500S controller.

Note:

This message only applies to the 3ware 9500S controller, which has

removable memory. Other 3ware controller models do not have memory that
can be removed.

Action

Replace the incompatible SO-DIMM with a compatible one.

See Also

For a list of SODIMMs compatible with the 9500S, see

http://www.3ware.com/KB/article.aspx?id=11748

.

0038 SO-DIMM not detected

Event Type

Error

Advertising