0032 spare capacity too small, 0033 migration started, 0034 migration failed – Avago Technologies 3ware 9650SE-12ML (Channel) User Manual
Page 294

Troubleshooting
282
3ware SAS/SATA RAID Software User Guide, Version 9.5.1
See Also
For a list of compatible drives, see
http://www.3ware.com/products/compatibility_sata.asp
0032 Spare capacity too small
Event Type
Warning
Cause
There is a valid hot spare but the capacity is not sufficient to use it for a drive
replacement in existing units.
Action
Replace the spare with a drive of equal or larger capacity than the existing
drives.
0033 Migration started
Event Type
Information
Cause
The 3ware RAID controller has started the migration of a unit.
Migration changes can include:
•
Expanding capacity of a unit by adding drives
•
Changing RAID levels, for example, from RAID 1 to RAID 5
See Also
“RAID Level Migration (RLM) Overview” on page 128
0034 Migration failed
Event Type
Error