0032 spare capacity too small, 0033 migration started, 0034 migration failed – Avago Technologies 3ware 9650SE-12ML (Channel) User Manual

Page 294

Advertising
background image

Troubleshooting

282

3ware SAS/SATA RAID Software User Guide, Version 9.5.1

See Also

For a list of compatible drives, see

http://www.3ware.com/products/compatibility_sata.asp

0032 Spare capacity too small

Event Type

Warning

Cause

There is a valid hot spare but the capacity is not sufficient to use it for a drive
replacement in existing units.

Action

Replace the spare with a drive of equal or larger capacity than the existing
drives.

0033 Migration started

Event Type

Information

Cause

The 3ware RAID controller has started the migration of a unit.

Migration changes can include:

Expanding capacity of a unit by adding drives

Changing RAID levels, for example, from RAID 1 to RAID 5

See Also

“RAID Level Migration (RLM) Overview” on page 128

0034 Migration failed

Event Type

Error

Advertising