12 ma output signals — a_led/, b_led/, hb_led – Avago Technologies LSI53C1030 User Manual

Page 130

Advertising
background image

5-6

Specifications

Version 2.2

Copyright © 2001, 2002, 2003 by LSI Logic Corporation. All rights reserved.

Table 5.9

Input Signals

1

— CLK, CLKMODE_0, CLKMODE_1, DIS_PCI_FSN/,

DIS_SCSI_FSN/, GNT/, IDDTN, IDSEL, IOPD_GNT/, PVT1, PVT2, SCANEN,
SCANMODE, SCLK, TCK_CHIP, TCK_ICE, TESTACLK, TESTCLKEN,
TESTHCLK, TDI_CHIP, TDI_ICE, TMS_CHIP, TMS_ICE, TN, TRST_ICE/,
TST_RST/, ZCR_EN/

Symbol

Parameters

Min

Max

Unit

Test Conditions

V

IH

Input high voltage

2.0

VDD + 0.5

V

V

IL

Input low voltage

0.3

0.8

V

I

IN

3-state leakage

10

10

µ

A

V

PIN

= 0 V,

VDD + 0.5 V

I

PULL-UP

Pull current

25

µ

A

1. Do not place pulls on CLK, GNT/, IDSEL, RST/, and SCLK. The pull information given does not

apply to these signals.

Table 5.10

8 mA Output Signals

1

— ADSC/, ADV/, ALT_INTA/, ALT_INTB/, BWE[1:0]/,

FLSHALE[1:0]/, FLSHCE/, INTA/, INTB/, MCLK, MOE/, PIPESTAT[2:0],
RAMCE/, REQ/, RTCK_ICE, SerialCLK, SERR/, TDO_CHIP, TDO_ICE,
TRACECLK, TRACEPKT[7:0], TRACESYNC

Symbol

Parameters

Min

Max

Unit

Test Conditions

V

OH

Output high voltage

2.4

VDD

V

8 mA

V

OL

Output low voltage

VSS

0.4 VDD

V

8 mA

I

OZ

3-state leakage

10

10

µ

A

V

PIN

= 0 V, 3.6 V

I

PULL-UP

Pull current

25

µ

A

1. Do not place pulls on REQ/ and SERR/. The pull information given does not apply to these signals.

Table 5.11

12 mA Output Signals — A_LED/, B_LED/, HB_LED/

Symbol

Parameters

Min

Max

Unit

Test Conditions

V

OH

Output high voltage

2.4

VDD

V

12 mA

V

OL

Output low voltage

VSS

0.4 VDD

V

12 mA

I

OZ

3-state leakage

10

10

µ

A

V

PIN

= 0 V, 3.6 V

I

PULL-UP

Pull current

25

µ

A

Advertising