PLANET GS-5220-16S8C User Manual

Page 86

Advertising
background image

User’s Manual of GS-5220 Series

Group Name

A string identifying the group name that this entry should belong to. The allowed

string length is 1 to 32, and the allowed content is the ASCII characters from 33

to 126.

Security Model

Indicates the security model that this entry should belong to. Possible security

models are:

any

: Accepted any security model (v1|v2c|usm).

v1

: Reserved for SNMPv1.

v2c

: Reserved for SNMPv2c.

usm

: User-based Security Model (USM)

Security Level

Indicates the security model that this entry should belong to. Possible security

models are:

NoAuth, NoPriv

: None authentication and none privacy.

Auth, NoPriv

: Authentication and none privacy.

Auth, Priv

: Authentication and privacy.

Read View Name

The name of the MIB view defining the MIB objects for which this request may

request the current values. The allowed string length is 1 to 32, and the allowed

content is the ASCII characters from 33 to 126.

Write View Name

The name of the MIB view defining the MIB objects for which this request may

potentially SET new values. The allowed string length is 1 to 32, and the allowed

content is the ASCII characters from 33 to 126.

Buttons

: Click to add a new access entry.

: Click to apply changes

: Click to undo any changes made locally and revert to previously saved values.

86

Advertising
This manual is related to the following products: