Erps guard-timeout, Erps wtr-timeout – PLANET MGSW-28240F User Manual
Page 616

User’s Manual of MGSW-28240F
erps guard-timeout
Description:
Configuring guard timeout for a protection group guard timeout should be configured in the increments of 10 milliseconds
minimum guard timeout 10ms and maximum 2 seconds.
<guard_timeout> : guard timeout.
<group-id> : protection group id for configuring guard time.
Syntax:
Erps guard-timeout <guard_timeout> <group-id>
Parameters:
<guard_timeout>: timer timeout values.
<group-id> : protection group id 1 – 64.
Example:
MGSW-28240F:/>erps guard-timeout 500 1
erps wtr-timeout
Description:
Configuring wait to restore timeout for a protection group in minutes in the range of 1 to 12 minutes.
<wtr_timeout> : configuring wtr timeout.
<group-id> : protection group id for configuring wtr time.
Syntax:
Erps wtr-timeout <wtr_timeout> <group-id>
Parameters:
<wtr_timeout>: timer timeout values.
<group-id> : protection group id 1 – 64.
616