erps guard-timeout

Description:

Configuring guard timeout for a protection group guard timeout should be configured in the increments of 10 milliseconds

minimum guard timeout 10ms and maximum 2 seconds.

<guard_timeout> : guard timeout.

<group-id> : protection group id for configuring guard time.

Syntax:

Erps guard-timeout <guard_timeout> <group-id>

Parameters:

<guard_timeout>: timer timeout values.

<group-id> : protection group id 1 – 64.

Example:

MGSW-28240F:/>erps guard-timeout 500 1

erps wtr-timeout

Description:

Configuring wait to restore timeout for a protection group in minutes in the range of 1 to 12 minutes.

<wtr_timeout> : configuring wtr timeout.

<group-id> : protection group id for configuring wtr time.

Syntax:

Erps wtr-timeout <wtr_timeout> <group-id>

Parameters:

<wtr_timeout>: timer timeout values.

<group-id> : protection group id 1 – 64.