PLANET WGSD-10020HP User Manual

Page 308

Advertising
background image

User’s Manual of WGSD-10020 Series

Figure 4-16-2:

PoE Configuration Screenshot

The page includes the following fields:

Object

Description

System PoE Admin

Mode

Allows user to enable or disable PoE function. It will cause all of PoE ports to

supply or not supply power.

PoE Temperature

Protection

Allows user to enable or disable PoE Temperature Protection.

PoE Management

Mode

There are Six modes for configuring how the ports/PDs may reserve power and

when to shut down ports.

Class-Consumption mode:

System offers PoE power according to PD real

power consumption.

Class-Reserved-Power mode:

System reserves PoE power to PD

according to PoE class level.

Allocation-Consumption mode:

System offers PoE power according to PD

real power consumption.

Allocation-Reserved-Power mode:

Users allow to assign how much PoE

power for per port and system will reserve PoE power to PD.

LLDP-Consumption mode:

System offers PoE power according to PD real

power consumption.

LLDP-Reserved-Power mode:

System reserves PoE power to PD

according to LLDP configuration.

Power Supply Budget

[W]

Set limit value of the total PoE port provided power to the PDs.

WGSD-10020HP

available maximum value is 150watts.

Temperature

Threshold

Allows setting over temperature protection threshold value. It system

temperature was over it then system lower total PoE power budget automatically.

PoE Usage Threshold

Allows setting how much PoE power budget could be limited.

Buttons

: Click to apply changes

: Click to undo any changes made locally and revert to previously saved values.

PD Classifications

A PD may be classified by the PSE based on the classification information provided by the PD. The intent of PD classification is

to provide information about the maximum power required by the PD during operation. However, to improve power management

at the PSE, the PD provides a signature about Class level.

The PD is classified based on power. The classification of the PD is the maximum power that the PD will draw across all input

voltages and operational modes.

308