Please Read This Notice

Successful application of this module requires a reasonable working knowledge of the Rockwell Automation
ControlLogix hardware, the MVI56-BSAPS Module and the application in which the combination is to be used. For
this reason, it is important that those responsible for implementation satisfy themselves that the combination will meet
the needs of the application without exposing personnel or equipment to unsafe or inappropriate working conditions.

This manual is provided to assist the user. Every attempt has been made to ensure that the information provided is
accurate and a true reflection of the product's installation requirements. In order to ensure a complete understanding
of the operation of the product, the user should read all applicable Rockwell Automation documentation on the
operation of the Rockwell Automation hardware.

Under no conditions will ProSoft Technology be responsible or liable for indirect or consequential damages resulting
from the use or application of the product.

Reproduction of the contents of this manual, in whole or in part, without written permission from ProSoft Technology
is prohibited.

Information in this manual is subject to change without notice and does not represent a commitment on the part of
ProSoft Technology Improvements and/or changes in this manual or the product may be made at any time. These
changes will be made periodically to correct technical inaccuracies or typographical errors.

Warnings

UL Warnings

A

Warning - Explosion Hazard - Substitution of components may impair suitability for Class I, Division 2.

B

Warning - Explosion Hazard - When in Hazardous Locations, turn off power before replacing or rewiring
modules.
Warning - Explosion Hazard - Do not disconnect equipment unless power has been switched off or the area is
known to be nonhazardous.

C

Suitable for use in Class I, division 2 Groups A, B, C and D Hazardous Locations or Non-Hazardous Locations.

ATEX Warnings and Conditions of Safe Usage:

Power, Input, and Output (I/O) wiring must be in accordance with the authority having jurisdiction

A

Warning - Explosion Hazard - When in hazardous locations, turn off power before replacing or wiring modules.

B

Warning - Explosion Hazard - Do not disconnect equipment unless power has been switched off or the area is
known to be non-hazardous.

C

These products are intended to be mounted in an IP54 enclosure. The devices shall provide external means to
prevent the rated voltage being exceeded by transient disturbances of more than 40%. This device must be
used only with ATEX certified backplanes.

D

DO NOT OPEN WHEN ENERGIZED.

Electrical Ratings

ƒ

Backplane Current Load: 800 mA @ 5 V DC; 3mA @ 24V DC

ƒ

Operating Temperature: 0 to 60°C (32 to 140°F)

ƒ

Storage Temperature: -40 to 85°C (-40 to 185°F)

ƒ

Shock: 30g Operational; 50g non-operational; Vibration: 5 g from 10 to 150 Hz

ƒ

Relative Humidity 5% to 95% (non-condensing)

ƒ

All phase conductor sizes must be at least 1.3 mm(squared) and all earth ground conductors must be at least
4mm(squared).