5.3 Speed Control (Analog Voltage Reference)

5-25

5

Op

er

at

io

n

5.3.7

Setting Encoder Output Pulse

Set the encoder output pulse using the following parameter.

Pulses from the encoder per revolution are divided inside the SERVOPACK by the number set in this parame-
ter before being output. Set the number of encoder output pulses according to the system specifications of the

machine or host controller.

According to the encoder resolution, the number of encoder output pulses are limited.

Note 1. An encoder output pulse setting error (A.041) will occur if the setting is outside the allowable range or does not

satisfy the setting conditions.
Pn212 = 25000 (P/Rev) is accepted, but
Pn212 = 25001 (P/Rev) is not accepted. The alarm A.041 is output because the setting unit differs from that in
the above table.

2. The upper limit of the pulse frequency is approx. 1.6 Mpps.

The servomotor speed is limited if the setting value of the encoder output pulses (Pn212) is large.
An overspeed of encoder output pulse rate alarm (A.511) will occur if the motor speed exceeds the upper limit
specified in the above table.

Output Example: When Pn212 = 16 (16-pulse output per one revolution), PAO and PBO are output as shown
below.

Pn212

Encoder Output Pulses

 

 

 

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

16 to 1073741824

1 P/rev

2048

After restart

Setup

Setting Range of

Encoder Output

Pulses (P/Rev)

Setting Unit

Encoder Resolution:

17 bits (131,072 pulses)

Upper Limit of Servomotor Speed

for Set Encoder Output Pulses

(min

-1

)

16 to 16384

1

6000

16386 to 32768

2

3000

Speed

Position

Torque

Preset value: 16