9.1 Alarm Displays

9-9

9

Trou

blesh

ooting

A.7A0:
Heat Sink Overheated

(Detected when the heat
sink temperature
exceeds 90

°

C.)

The surrounding air temperature
is too high.

Check the surrounding air tempera-
ture using a thermostat.

Decrease the surrounding air tem-
perature by improving the SERVO-
PACK installation conditions.

The overload alarm has been
reset by turning OFF the power
too many times.

Check the alarm history display
(Fn000) to see if the overload alarm
was reported.

Change the method for resetting the

alarm.

Excessive load was applied dur-
ing operation.

Check the accumulated load ratio
(Un009) to see the load during oper-

ation.

Reconsider the load conditions and
operating conditions.

Incorrect SERVOPACK installa-

tion orientation or/and insuffi-
cient space around the
SERVOPACK.

Check the SERVOPACK installa-
tion conditions.

Install the SERVOPACK correctly
as specified.

A SERVOPACK fault occurred.

The SERVOPACK may be faulty.
Replace the SERVOPACK.

A.810:
Encoder Backup Error

(Only when an absolute

encoder is connected.)
(Detected on the encoder

side.)

Alarm occurred when the power

to the absolute encoder was ini-

tially turned ON.

Check to see if the power was

turned ON initially.

Set up the encoder (Fn008).

The encoder cable disconnected,

and connected again.

Check to see if the power was

turned ON initially.

Confirm the connection and set up

the encoder (Fn008).

The power from both the control

power supply (+5 V) from the

SERVOPACK and the battery

power supply is not being sup-

plied.

Check the encoder connector bat-

tery or the connector contact status.

Replace the battery or take similar

measures to supply power to the

encoder, and set up the encoder

(Fn008).

An absolute encoder fault

occurred.

If the alarm cannot be reset by set-

ting up the encoder again, replace

the servomotor.

A SERVOPACK fault occurred.

The SERVOPACK may be faulty.

Replace the SERVOPACK.

A.820:
Encoder Checksum

Error

(Detected on the encoder

side.)

An encoder fault occurred.

• Absolute encoder

Set up the encoder again using
Fn008. If the alarm still occurs,
the servomotor may be faulty.
Replace the servomotor.

• One-turn absolute encoder or

incremental encoder
The servomotor may be faulty.
Replace the servomotor.

A SERVOPACK fault occurred.

The SERVOPACK may be faulty.

Replace the SERVOPACK.

A.830:
Absolute Encoder

Battery Error

(The absolute encoder

battery voltage is lower

than the specified value.)

The battery connection is incor-

rect.

Check the battery connection.

Reconnect the battery.

The battery voltage is lower than

the specified value 2.7 V.

Measure the battery voltage.

Replace the battery.

A SERVOPACK fault occurred.

The SERVOPACK may be faulty.

Replace the SERVOPACK.

A.840:
Encoder Data Error

(Detected on the encoder
side.)

An encoder malfunctioned.

Restart the SERVOPACK. If the

alarm still occurs, the servomotor

may be faulty. Replace the servo-

motor.

Malfunction of encoder because

of noise interference, etc.

Correct the wiring around the

encoder by separating the encoder

cable from the servomotor main cir-

cuit cable or by checking the

grounding and other wiring.

(cont’d)

Alarm Number:

Alarm Name

(Alarm Description)

Cause

Investigative Actions

Corrective Actions

Advertising