6.3 Advanced Autotuning (Fn201)

6-17

6

Adjustments

Advanced autotuning performs the following adjustments.

• Moment of inertia ratio
• Gains (e.g., position loop gain and speed loop gain)
• Filters (torque reference filter and notch filter)
• Friction compensation
• Anti-resonance control
• Vibration suppression (Mode = 2 or 3)

Refer to

6.3.3 Related Parameters

for parameters used for adjustments.

(1) Preparation

The following conditions must be met to perform advanced autotuning.

The message “NO-OP” indicating that the settings are not appropriate will be displayed, if all of the following

conditions are not met.

• The main circuit power supply must be ON.
• There must be no overtravel.
• The servo ON signal (/S-ON) must be OFF.
• The control method must not be set to torque control.
• The gain selection switch must be in manual switching mode (Pn139.0 = 0).
• Gain setting 1 must be selected.
• The test without a motor function must be disabled (Pn00C.0 = 0).
• All alarms and warning must be cleared.
• The write prohibited setting parameter (Fn010) must be set to Write permitted (P.0000).
• Jcalc must be set to ON to calculate the load moment of inertia when the tuning-less function is enabled

(Pn170.0 = 1: factory setting) or the tuning-less function must be disabled (Pn170.0 = 0).

Notes:

• If advanced autotuning is started while the SERVOPACK is in speed control, the mode will change to position

control automatically to perform advanced autotuning. The mode will return to speed control after completing the
adjustment. To perform advanced autotuning in speed control, set the mode to 1 (Mode = 1).

• The reference pulse input multiplication switching function is disabled while performing advanced autotuning.

(2) When Advanced Autotuning Cannot Be Performed

Advanced autotuning cannot be performed normally under the following conditions. Refer to

6.4 Advanced

Autotuning by Reference (Fn202) (Pulse Train Reference)

and

6.5 One-parameter Tuning (Fn203)

for details.

• The machine system can work only in a single direction.
• The operating range is within 0.5 rotation.

CAUTION

• Because advanced autotuning adjusts the SERVOPACK during automatic operation, vibration or over-

shooting may occur. To ensure safety, perform advanced autotuning in a state where the SERVOPACK

can come to an emergency stop at any time.