2 i/o signal connections, 1 i/o signal (cn1) names and functions, 1) input signals – Yaskawa Σ-V Series AC Servo Drives Rotational Motor Analog Voltage Reference User Manual

Page 43

Advertising
background image

3 Wiring and Connection

3.2.1 I/O Signal (CN1) Names and Functions

3-8

3.2

I/O Signal Connections

This section describes the names and functions of I/O signals (CN1). Also connection examples by control

method are shown.

3.2.1

I/O Signal (CN1) Names and Functions

The following table shows the names and functions of I/O signals (CN1).

(1) Input Signals

Control

Method

Signal

Name

Pin No.

Function

Refer-

ence

Section

Common

/S-ON

15

Servo ON/OFF: Turns ON/OFF the servomotor.

5.2.1

/P-CON

16

Proportional con-
trol reference

Switches the speed control loop from PI (propor-
tional/integral) to P (proportional) control when
ON.

6.9.3

Rotation Direc-
tion reference

With internal set speed control selected: Switches
the servomotor rotation direction.

5.6.1

Control switch-
ing

Switches control method between torque control
and speed control.

5.7.2

Zero-clamp refer-
ence

With speed control with zero-clamp function
selected: Reference speed is zero when ON.

5.3.5

Reference pulse
block

With position control with reference pulse stop
selected: Stops reference pulse input when ON.

5.4.8

P-OT
N-OT

17
18

Forward run
prohibited,
Reverse run
prohibited

With overtravel prevention: Stops servomotor
when movable part travels beyond the allowable
range of motion.

5.2.3

/P-CL

26

Forward external
torque limit

Activates/deactivates external torque limit func-
tion.

5.8.2
5.8.4

/N-CL

12

Reverse external

torque limit

Internal set speed
switching

With internal set speed control selected: Switches
the internal set speed settings.

5.6.1

/ALM-RST 25

Alarm reset: Releases the servo alarm state.

+24VIN

14

Control power supply input for sequence signals
Allowable voltage range: 11 to 25 V
Note: The 24 VDC power supply is not included.

3.4.2

/SEN
/SPD-D
/SPD-A
/SPD-B
/C-SEL
/ZCLAMP
/INHIBIT
/G-SEL
/PSEL

Can be

allocated

The following input signals can be changed to allocate functions:
/S-ON, /P-CON, P-OT, N-OT, /P-CL, /N-CL, and /ALM-RST.

3.3.1
5.3.5
5.4.3
5.4.8
5.6.1

5.7.1
6.8.1

Analog

Voltage

Reference

V-REF

1 (2)

Inputs speed reference. Input voltage range:

±

12 V max.

5.3.1
5.5.4

T-REF

3 (4)

Inputs torque reference. Input voltage range:

±

12 V max.

5.5.1
5.8.3
5.8.5

Advertising