10.2.2 Parameters
10-20
Pn50A
2
Input Signal Selection 1
0000 to FFF1
−
2100
After restart
Setup
−
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classification
Reference
Section
4th 3rd 2nd 1st
digit digit digit digit
n.
Input Signal Allocation Mode
Reference
Section
0
Uses the sequence input signal terminals with the factory-set allocations.
3.3.1
1
Changes the sequence input signal allocation for each signal.
Servo ON (/S-ON) Signal Mapping
Signal Polarity: Normal; Servomotor power ON when ON (L-level)
Signal Polarity: Reverse; Servomotor power OFF when OFF (H-level)
Reference
Section
0
Active when CN1-15 input signal is ON (L-level).
5.2.1
1
Active when CN1-16 input signal is ON (L-level).
2
Active when CN1-17 input signal is ON (L-level).
3
Active when CN1-18 input signal is ON (L-level).
4
Active when CN1-25 input signal is ON (L-level).
5
Active when CN1-26 input signal is ON (L-level).
6
Active when CN1-12 input signal is ON (L-level).
7
Always active (fixed).
8
Not active (fixed).
9
Active when CN1-15 input signal is OFF (H-level).
A
Active when CN1-16 input signal is OFF (H-level).
B
Active when CN1-17 input signal is OFF (H-level).
C
Active when CN1-18 input signal is OFF (H-level).
D
Active when CN1-25 input signal is OFF (H-level).
E
Active when CN1-26 input signal is OFF (H-level).
F
Active when CN1-12 input signal is OFF (H-level).
/P-CON Signal Mapping (P control when ON (L-level))
Reference
Section
0 to F
Same as Servo ON Signal (/S-ON) Mapping.
6.9.3
P-OT Signal Mapping (Forward run prohibited when OFF (H-level))
Reference
Section
0
Forward run allowed when CN1-15 input signal is ON (L-level).
5.2.3
1
Forward run allowed when CN1-16 input signal is ON (L-level).
2
Forward run allowed when CN1-17 input signal is ON (L-level).
3
Forward run allowed when CN1-18 input signal is ON (L-level).
4
Forward run allowed when CN1-25 input signal is ON (L-level).
5
Forward run allowed when CN1-26 input signal is ON (L-level).
6
Forward run allowed when CN1-12 input signal is ON (L-level).
7
Forward run prohibited.
8
Forward run allowed.
9
Forward run allowed when CN1-15 input signal is OFF (H-level).
A
Forward run allowed when CN1-16 input signal is OFF (H-level).
B
Forward run allowed when CN1-17 input signal is OFF (H-level).
C
Forward run allowed when CN1-18 input signal is OFF (H-level).
D
Forward run allowed when CN1-25 input signal is OFF (H-level).
E
Forward run allowed when CN1-26 input signal is OFF (H-level).
F
Forward run allowed when CN1-12 input signal is OFF (H-level).