3.2 I/O Signal Connections
3-11
3
Wi
ring and
C
onne
ctio
n
3.2.3
Example of I/O Signal Connections in Position Control (Pulse Train
Reference)
Connection example in position control is as shown below.
∗1.
represents twisted-pair wires.
∗2.
If using an absolute encoder, allocate the SEN signal to one of the seven input signals.
∗3.
The 24-VDC power supply is not included. Use a 24-VDC power supply with double insulation or reinforced insula-
tion.
∗4.
Always use line receivers to receive the output signals.
PBO
PCO
/PBO
PAO
/PAO
/PCO
/COIN
ALM
/TGON
/S-RDY
COM SG
8
9
10
11
7
23
19
20
21
22
24
+24 V
+24 VIN
3.3 k
Ω
/S-ON
/P-CON
P-OT
N-OT
/ALM-RST
/N-CL
14
16
18
17
25
26
/P-CL
12
15
∗
3
CLR
SERVOPACK
FG
/PULS
SIGN
/SIGN
PULS
∗
1.
CN1
6
5
150
Ω
CLR
/CLR
4
3
150
Ω
2
1
150
Ω
∗
2
∗
4
∗
4
∗
4
13
SG
PULS
SIGN
Servo ON
(Servo ON when ON)
Reverse run prohibited
(Prohibited when OFF)
Forward run prohibited
(Prohibited when OFF)
Alarm reset
(Reset when ON)
Reverse external torque limit
(Limit when ON)
Forward external torque limit
(Limit when ON)
P control
(P control when ON)
Position
reference
CW
Phase A
CCW
Phase B
Positioning completed
(ON when positioning
completes.)
Rotation detection output
(ON when the motor speed
exceeds the settings.)
Servo ready output
(ON when ready)
Servo alarm output
(OFF for an alarm)
Photocoupler output
Max. operating voltage:
30 VDC
Max. output current:
50 mA DC
Applicable line
receiver:
SN75ALS175 or
MC3486
manufactured by
Texas Instruments
or the equivalent
Encoder output
pulse phase A
Encoder output
pulse phase B
Encoder output
pulse phase C
Connect shield to
connector shell.
Connector
shell
SERVOPACK
Analog