5.4 Position Control (Pulse Train Reference)

5-39

5

Op

er

at

io

n

5.4.8

Reference Pulse Inhibit Function

This function inhibits the SERVOPACK from counting input pulses during position control. When this func-

tion is enabled, the SERVOPACK does not accept the reference pulse input.

(1) Factory-set Input Signal Allocations (Pn50A.0 = 0)

Use Pn000.1=B and the /P-CON signal to use the reference pulse inhibit function while the input signal allo-
cations are still in the factory settings.

Note: If Pn000.1 is set to B, the /P-CON signal cannot be used for any function other than the reference pulse inhibit func-

tion.

(2) Changing Input Signal Allocations (Pn50A.0 = 1)

Allocate the /INHIBIT signal as the reference pulse inhibit signal to use the reference pulse inhibit function

while the Pn000.1 (control method) is set to 1 or 5.

Note: Use parameter Pn50D.1 to allocate the /INHIBIT signal for use. For details, refer to

3.3.1 Input Signal Allocations

to

Input Terminals

.

To use the reference pulse inhibit function, set Pn000.1 to 1 or 5.

Note: Reference pulse inhibit function is effective only with position control.

Type

Signal

Name

Connector

Pin Number

Setting

Meaning

Input

/P-CON

CN1-16
[Factory setting]

ON (closed)

Stops counting the reference pulses.

OFF (open)

Counts the reference pulses.

Parameter

Control Method

Input Signal

Used

When Enabled Classification

Pn000

n.

B

Position Control

Position Control

with Reference Pulse Inhibit Function

/P-CON

After restart

Setup

Type

Signal

Name

Connector

Pin Number

Setting

Meaning

Input

/INHIBIT

Must be allocated.

ON (closed)

Stops counting the reference pulses.

OFF (open)

Counts the reference pulses.

Parameter

Control Method

Input Signal

Used

When Enabled Classification

Pn000

n.

1

Position Control

/INHIBIT

After restart

Setup

n.

5

Internal Set Speed Control

Position

Control

/INHIBIT
/SPD-A
/SPD-B
/SPD-D
/C-SEL