PRIME / ProArt / TUF GAMING Intel 700 Series BIOS Manual

The following items appear only when

Chassis Fan 1-5 Profile

is set to

[Manual].

Chassis Fan Point4 Temperature

When the temperature source is lower than the temperature of P4, the duty cycle will be

determined according to the P3-P4 and the temperature source. When the temperature

source is higher than the temperature of P4, the fan will operate at the duty cycle of P4.
Use the <+> or <-> keys to adjust the temperature.

Chassis Fan Point4 Duty Cycle (%)

When the temperature source is lower than the temperature of P4, the duty cycle will be

determined according to the P3-P4 and the temperature source. When the temperature

source is higher than the temperature of P4, the fan will operate at the duty cycle of P4.

Use the <+> or <-> keys to adjust the fan/pump duty cycle.

Chassis Fan Point3 Temperature

When the temperature source is lower than the temperature of P3, the duty cycle will be

determined according to the P2-P3 and the temperature source. When the temperature

source is higher than the temperature of P3, the fan will operate at the duty cycle of P3-

P4. Use the <+> or <-> keys to adjust the temperature.

Chassis Fan Point3 Duty Cycle (%)

When the temperature source is lower than the temperature of P3, the duty cycle will be

determined according to the P2-P3 and the temperature source. When the temperature

source is higher than the temperature of P3, the fan will operate at the duty cycle of P3-

P4. Use the <+> or <-> keys to adjust the fan/pump duty cycle.

Chassis Fan Point2 Temperature

When the temperature source is lower than the temperature of P2, the duty cycle will be

determined according to the P1-P2 and the temperature source. When the temperature

source is higher than the temperature of P2, the fan will operate at the duty cycle of P2-

P3. Use the <+> or <-> keys to adjust the temperature.

Chassis Fan Point2 Duty Cycle (%)

When the temperature source is lower than the temperature of P2, the duty cycle will be

determined according to the P1-P2 and the temperature source. When the temperature

source is higher than the temperature of P2, the fan will operate at the duty cycle of P2-

P3. Use the <+> or <-> keys to adjust the fan/pump duty cycle.

Chassis Fan Point1 Temperature

When the temperature source is lower than the temperature of P1, the fan will operate at

the duty cycle of P1. When the temperature source is higher than the temperature of P1,

the duty cycle will be determined according to P1-P2 and the temperature source. Use

the <+> or <-> keys to adjust the temperature.

Chassis Fan Point1 Duty Cycle (%)

When the temperature source is lower than the temperature of P1, the fan will operate at

the duty cycle of P1. When the temperature source is higher than the temperature of P1,

the duty cycle will be determined according to P1-P2 and the temperature source. Use

the <+> or <-> keys to adjust the fan/pump duty cycle.

Allow Fan Stop

This function allows the fan to run at 0% duty cycle when the temperature of the source is

dropped below the lower temperature.

Configuration options: [Disabled] [Enabled]