AIO Pump Q-Fan Control

Allows you to set the AIO Pump operating mode.
[Auto Detect]

Detects the type of installed fan/pump and automatically switches

the control modes.

[DC Mode]

Enables the Q-Fan Control feature in DC mode for 3-pin fan/pump.

[PWM Mode]

Enables the Q-Fan Control feature in PWM mode for 4-pin fan/

pump.

AIO Pump Profile

Allows you to set the appropriate performance level of the assigned fan/pump. When

selecting

[Manual]

, we suggest raising your fan/pump duty to 100% if your CPU

temperature exceeds 75°C. Please be noted CPU performance will throttle due to

overheating with inefficient fan/pump duty.

Configuration options: [Standard] [Silent] [Turbo] [Full Speed] [Manual]

The following items appear only when

AIO Pump Profile

is set to

[Standard]

,

[Silent]

,

[Turbo]

, or

[Manual].

AIO Pump Q-Fan Source

The assigned fan/pump will be controlled according to the selected temperature

source.

Configuration options: [CPU] [MotherBoard] [VRM] [Chipset] [T_Sensor] [Multiple

Sources]

AIO Pump Step Up

Step up allows you to adjust how quickly the fan rotation speed increases, with level 0

being an instantaneous change in speed. The higher the level, the slower the change

in speed, and may also result in less noise, but this will also cause slower heat

dissipation.

Configuration options: [Level 0] [Level 1] [Level 2] [Level 3] [Level 4] [Level 5]

AIO Pump Step Down

Step down allows you to adjust how quickly the fan rotation speed decreases, with

level 0 being an instantaneous change in speed. The higher the level, the slower the

change in speed, and may also result in less noise, but this will also cause slower

heat dissipation.

Configuration options: [Level 0] [Level 1] [Level 2] [Level 3] [Level 4] [Level 5]

AIO Pump Speed Low Limit

Allows you to set the lower speed limit for assigned fan/pump. A warning message will

appear when the limit is reached; the warning message will not appear if

[Ignore]

is

selected.

Configuration options: [Ignore] [200 RPM] [300 RPM] [400 RPM] [500 RPM] [600

RPM]