PIM-SM (Sparse Mode)
Event Log Messages

Message

Meaning

Rcvd unkwn addr fmly <

add-family> in

<

pkt-type> pkt from < ip-addr >

A PIM packet with an unknown address family was
received.

Rcvd <

pkt-type> pkt with bad len from

< ip-addr >

A PIM packet with an inconsistent length was received from
the indicated IP address.

Send error(

< error-# >) on < packet-type >

pkt on VID

< vid-# >

Send packet failed on the indicated VLAN.

Static RP configuration failure:
< src-ip-addr >, < multicast-addr >

The configuration of a static RP for the indicated multicast
group has failed on the indicated interface.

Unable to alloc a buf of size

< size >

for

< memory element >

PIM_DM could not allocate memory for the indicated buffer.

Unable to alloc a msg buffer for
< system-event >

Informs the user that a message buffer could not be
allocated for the indicated system event.

Unable to allocate <

table-type> table

The PIM interface has been removed due to an IP address
removal or change.

Unexpected state/event

< state >/<event >

in

< statemachine > statemach

PIM received an event type in a state that was not expected.

VLAN is not configured for IP.

A VLAN must be statically configured with a primary IP
address before enabling PIM-SM on that VLAN. If the VLAN
has no IP address or is configured to acquire a primary IP
address by using DHCP/Bootp, it cannot be configured to
support PIM-SM.

4-70