M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l

6

Note: Pins (4,5) and (7,8) of the management RJ45 connector can be used for dry
contact purposes, for Airlink flag and F/O flag alarms respectively.



Selectors

(DIP Switch

DS1 Toggles)

-- shown in

Figure 1.3and
1.4

Data Rate
(Toggles 1,2,3,4)

Set the transmission rate of the transceiver (internal
clock).
- Fast Ethernet: 1,2,3,4 OFF
- ATM/OC3/STM1:155 Mbps: 2,3,4 OFF, 1 ON

- SMPTE 143 Mbps: 3,4 OFF, 1,2 ON
- E3: 34.368 Mbps1,2,4 OFF, 3 ON
- T3: 44.736 Mbps: 2,4 OFF, 1,3 ON
- OC1/STM0: 51.840 Mbps: 1,4 OFF, 2,3 ON

- Customized 1 : 4 OFF, 1,2,3 ON
- Customized 2 : 1,3,4 OFF, 2 ON
- Open Protocol: 1,2,3 OFF, 4 ON.

Mode Select
(Toggles 1, 2, 3)

Set the Operating Mode
ALIGNMENT = Idle transmitted automatically

NORMAL = Signal received via the F/O port is
transmitted through the Airlink TX. Signal received
via the Airlink RX is transmitted through the F/O
TX.

LOOPBACK= Data received by the F/O RX is
directly returned through the F/O TX.
REMOTE LOOP = Loops the electrical RX to the
electrical TX and optical RX to the optical TX of the

remote unit.
ATTENUATION: The alignment signal is
attenuated (~20db) when the DIP switch toggle #3
is moved to ON position.(to use when the

installation distance is less than 200m only for
alignment mode). Switch back to OFF position for
normal mode.

Laser Power Off
(Toggle 4)

Turning off laser TX when the DIP switch toggle is
moved to ON

Fusion

(Toggle 5)

This switch toggle enables working with MRV’s

Fusion system (Built-in fusion option or switch
option). For additional information, see page 7.
Switch toggle 5 OFF: Fusion not Active (Disabled)
Switch toggle 5 ON: Fusion active (Enabled).

Window Heater

(Optional)
(Toggle 6)

Used only with the heating option (To be specified

in the PO).
Switch toggle 6 OFF: The heater is disabled
Switch toggle 5 ON: The heater is enabled.

IP address set up
(Toggle 7)

When the Switch toggle is on OFF position, the
TereScope’s IP address is the default one (shown on

the back panel label: 10.0.0.101). To set a new IP
address please refer to the “IP address setting
procedure for TereScope management card” file in
the Manuals CD. The new IP address is valid only

after the TereScope is powered off and on.

Selectors

(DIP Switch

DS2 Toggles)

-- shown in
Figure 1.3
and
1.4

Control Mode
(Toggle 8)

When the Dip Switch toggle #8 is on OFF position,
the TereScope is in the HARDWARE mode, i.e. the
TereScope is controlled only by the TereScope itself
by means of the switches on its back panel.

When the Dip Switch toggle is on ON position, the
TereScope is in the SOFTWARE mode i.e. the
TereScope is controlled by the management
Software and various functions can be activated by

means of this management Software.