MRV Communications TERESCOPE TS800/155 User Manual

Page 19

Advertising
background image

M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l

9







That’s what
happens when
the air channel
is interrupted.

F/O

Network

RF Transceiver

10/100TX-100FX
Media Converter

Switch

10/100 Base-T

MC

10 Base-T

STP

F/O

Main

TS

TS

IR = 100 Mbps

Network

Main

RF Transceiver

RF = 2-10 Mbps

F/O

F/O

10 Base-T

STP

Redundant

Redundant

Figure 1.5a: TereScope800/155 F - & Fusion System Connection

For a description of the Back Panel and all the functions, see Paragraph B table 3, and
Paragraph C Figure 1.4 – TS800 with Fusion model, page 8.

Fusion Operation Mode

When at least one of the air channels (IR) is cut for more than one second or drops to
approximately 60 mV at the display readout:

1. TereScope switches to Fusion mode
2. Data is transmitted from Main module to Redundant module without passing

through the air channel

3. The signal is converted to 10Base-T by the Switch and the data Rate decreases

to 2-10 Mbps

The system switches back to IR channel (TereScope) only when the display readout on both

sides increases to approximately 150 mV.

Note: To activate the Fusion option, set DIP Switch toggle 5 to the ON position.