Compatibility, Test equipment, Setup – MRV Communications TERESCOPE TS800/155 User Manual

Page 37

Advertising
background image

M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l

27

Table 6: DIP Switch Setting for TereScope

TS700/155 TS800/155

Function

OFF ON OFF ON

Fast Ethernet

4,5 –

1,2,3,4

ATM/OC3/STM1: 155 Mbps

4,5

2,3,4

1

SMPTE 143 Mbps

– 3,4

1,2

E3:34.368 Mbps

5

4

1,2,4 3

T3:44.736 4

5

2,4 1,3

OC1/STMO:51.840 Mbps

1,4 2,3

Customized 1

4 1,2,3

Customized 2

1,3,4 2

Open Protocol

1,2,3 4

Mode Select DIP switch toggle
Set DIP switch toggles 1 and 2 to the OFF position for normal operation. (In

TS800/155 and TS800/155-F set the DS2 1, 2, 3 and 4 toggles to OFF position)

2 – TS700/100 (Fast ethernet)

Compatibility

Peripheral equipment
Check the operation of the peripheral equipment connected with cables (see

Configuration 1 below).

Interfaces
Check the specifications compatibility (type, data rate) between the TereScope and
the peripheral equipment interfaces.

Test equipment

Chose an appropriate Bit Error Rate (BER) tester for checking the physical link
quality. A portable one is preferable since it is more convenient for use in the field.


A ping test or a file transfer between two workstations - connected to the

networking equipment - is useful and easy to implement for testing the
performance of the whole configuration.

Setup

DIP Switch

Set DIP switch toggles 1 and 2 to the OFF position for normal operation.

Set DIP switch toggle 4 for the speed. Usually with Cisco Switches set the TS to

Auto-negociation mode.