18

Prefer

Avoid

Pay attention to

Concrete Parapet
Structural wall or

column

Old constructions
Soft material (asphalt, etc.)

Non-uniform surfaces

Wooden and metal

structures

Colored windows

Double glazing

The proximity of power
radio antennas

For reasons of convenience, it is always preferable to install
the units indoors as long as all the required conditions
previously described are met and the customer/building
owner allows it. However, when windows are present in the
beam path, the attenuating factor of the glass must be
considered regarding the distance and the required fade
margin.

2. Referring to the data in Appendix A: Product Specifications,

set and record the distance between the two TereScopes of the
link. (You can use any of the following equipment to determine

the distance: rangefinder laser binoculars, GPS receiver, maps,
etc.)

3. Noting that two TereScope units are required per link, record

the quantity of each model of the TereScope required.

4. Record the bearing to the opposite site by compass.
5. Record the number of links to be installed at the site.
6. Note whether additional sheltering is needed for the

TereScope, for e.g., against strong winds (120km/h or more)


CONSULT FACTORY IN CASE OF DOUBT !

Figure 2.1 and Figure 2.2 show optimal and acceptable locations for the TereScope
links. Notice that in both figures the TereScopes are mounted on rooftop edges

and high enough above the ground.

(1)

In case such situations

cannot be avoided, special

mounting accessories and

techniques must be designed
and considered (see section

Particular Figure

Cases\Techniques page 37)

&&&&

TereScope mounted at corner of
leading edge of structure.