Aiming procedure, Chapter – MRV Communications TERESCOPE TS800/155 User Manual

Page 49

Advertising
background image

M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l

39

1 – Make sure that the power cable is disconnected

from the electrical power source.
2 – Undo the five screws H -- see Figure 6.1. Holding

the Rear Door, Pull the door, turn it clockwise ¼ of a

turn around the axis (I), so that a screw will be

opposite hole ”O”. Fixe the door on the hole ”O”

with the screw.

3 – Connect the wires of the power cable (see Figure 6.4)

to the Terminal Block (see Figure 6.5) paying attention to

L=Line, G=Ground & N=Neutral.

4 – After connecting the power cables to corresponding sockets,

tightly close the screws of the Terminal block –
see Figure 6.5. Gently jerk the cable to check that it stays connected.

Cover the Terminal Block with a plastic cover (if available).

Fig. 6.5: Power Terminal Block Locked

6 – Rotate and push the Back Door up, and tighten

the five H screws.

7 – Connect the power cable to the electrical power

source to power on the TereScope.

Captive
Screws H

5 – Cover the Terminal Block with the power supply cover.

Fig. 6.6: Power Cable and Fiberoptic Cable

Aiming Procedure

Point to point connections require the orientation face to face of both “transceiving” ends
of the link. Concerning wireless optical links, this should be done as accurately as
possible in order to position the beam symmetrically all around the remote receiver

.

Powering on the TereScope































Chapter

6

Fig. 6.1: Screws H and door axis

Fig. 6.4: Power cable & Terminal block

Fig. 6.2: Back Door Rotated ¼ of a turn

Door axis I

Fig. 6.

3

: View on Door axis

Fig. 6.7: Power Supply Cover

Power Supply
Cover

Fiberoptic Cable

Power Cable

Door axis I

Back Door

Hole “O”

and the
opposite
screw

Door axis I

Advertising