M R V C o m m u n i c a t i o n s , I n c . – I n s t a l l a t i o n M a n u a l

25

A simple power loss test can inform us about the condition of the

fibers. This test consists in measuring (with an optical power meter)
the output power at one end of the tested fiber when a fiber source is

connected at the other end. If the values are in dBm, the difference
between the input power and the output power gives the power

attenuation of the fiber (in dB).

Optical Power Meter

dBm

Peripheral

Equipment

or

Optical Source

F/O

TX

Fiber Optic

Cable

In case the above equipment is not available, a simple visual test may
be performed to locate and reject badly damaged fibers. Place a light

source at one end of the fiber and intermittently block it and observe
the light coming out of the other end. (This procedure does not

guarantee that a fiber is acceptable)

A standard 62.5

µµµµ

m fiber optic cable is characterized by an

attenuation factor of about 3 to 5 dB/km. A loss value of more

than 3 dB for runs up to 200m indicates that the fiber may be
faulty.

Note

The fiberoptic cables must be installed by a qualified person.

HANDLE THE FIBERS VERY CAREFULLY.

2. For TS700/100

Type

For connecting the Transceiver to the peripheral equipment, 2-pair

STP Category 5 cable is required (one pair for transmission, the other
for reception). This cable must be a straight one when the peripheral

has an MDI-X 100Base-TX interface and a Cross one otherwise.

For PoE (Power over Ethernet), 2 more pairs STP Category 5 cable are

required. (Use only for the Low Voltage version: TS100/A/FET/V3)

Connectors

The cable should be terminated with an RJ-45 connector at the
Transceiver end.

(

!

Figure 3.1: F/O cable test.