7 monitor: odu, 1 monitor: odu ( buc, 2 monitor: odu ( lnb – Mocomtech CDM-QX User Manual

Page 115: 1 monitor: odu æ buc, 2 monitor: odu æ lnb

Advertising
background image

CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier®

Revision 7

Front Panel Operation

MN/CDMQX.IOM

5–49

IMPORTANT

5.5.7

MONITOR: ODU

These read-only screens are operable only for CDM-QxL L-Band units.

Outdoor Unit Monitor:
BUC LNB (◄ ►,ENT)

Select BUC or LNB, using the ◄ ► arrow keys, then press

ENTER

.

5.5.7.1 MONITOR: ODU

Æ BUC

BUC: DC=47.8V,3.2A T=38oC
SW=1.1 PLL=Flt Pwr=02.1W

In this example, the BUC parameters displayed are as follows:

DC Pwr

(DC Power)

If a BUC supply is installed, displays measured BUC supply voltage and load

current, measured at the Tx-IF connector.

T

(Temperature)

If BUC FSK is enabled, displays BUC ambient temperature in

°C.

SW

If BUC FSK is enabled, displays the M&C software version of the BUC.

PLL

If BUC FSK is enabled, displays the fault status of the BUC PLL synthesizers.

Pwr

(Output)

If BUC FSK is enabled, displays the output power as measured by the BUC power

monitor.

Press

ENTER

or

CLEAR

to return to the previous menu.

5.5.7.2 MONITOR: ODU

Æ LNB

LNB Voltage: 13.1 volts
LNB Current: 235 mA (ENT)

In this example, the LNB parameters displayed are as follows:

LNB Voltage

LNB Voltage (in volts).

LNB Current

LNB Current, in mA.

Press

ENTER

or

CLEAR

to return to the previous menu.