Mocomtech CDM-QX User Manual

Page 248

Advertising
background image

CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier® Revision

7

Appendix C

MN/CDMQX.IOM

C–30

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

RX Signal
Level

N/A

4 bytes

Query Only.

Unit returns the value of the RX signal Level, in dBm, between –20
and –99 dBm, in the form ccxx, where:

cc=code: GT=Greater Than; LT=Less Than; = is equal to
xx=value (the ‘-‘ sign is implied)

Example:
RSL=LT99 (RX signal level is less than –99 dBm)
RSL===41 (RX signal level is equal to –41 dBm)

N/A RSL?

RSL=ccxx
(see Description of
Arguments)

Serial
Number of
Base Unit

N/A

9 bytes

Query only.

Used to query the 9-digit serial number of the Qx base unit in the
form: xxxxxxxxx

N/A SNM?

SNM=xxxxxxxxx
(see Description of
Arguments)

Serial
Number of
Modulator or
Demodulator

N/A

9 bytes

Query only.

Used to query the modulator or demodulator module 9-digit serial
number. It returns its S/N in the form xxxxxxxxx

N/A SNO?

SNO=xxxxxxxxx
(see Description of
Arguments)

Serial
Number of
turbo module

N/A

9 bytes

Query only.

Used to query the 9-digit serial number of the Turbo Codec module.

N/A SNT?

SNT=xxxxxxxxx
(see Description of
Arguments)

Software
Revision

N/A

34-37 bytes

Query only.

Units returns the value of the internal software revision installed in
the unit, in the form:

Boot:x.y.z Bulk1:x.y.z Bulk2:x.y.z
or
Boot:x.y.zz Bulk1:x.y.zz Bulk2:x.y.zz

N/A SWR?

SWR=Boot:x.y.zz
Bulk1:x.y.zz Bulk2:x.y.zz
(see Description of
Arguments)

Temperature
of Modulator

N/A

3 bytes

Query only.

It returns the value of the internal module temperature, in the form
of sxx (degrees C), where:

s=sign (+ or – character)
xx=value

Example: TMP=+26

N/A TMP?

TMP=sxx

(see Description of
Arguments)

Unit Type

N/A

11 bytes

Query only.

Type of plug-in identified in the form aw,bx,cy,dz, where:
a,b,c,d w,x,y,z

0=unoccupied 0=unoccupied
1=transmit 1=70/140 MHz
2=receive 2=L-Band
3=Reserved
4=Reserved

aw=Slot#1, bx=Slot#2, cy=Slot#3, dz=Slot#4

Example: WHO=00, 11, 21, 00, (Slot#1=empty, Slot#2=Tx,
Slot#3=Rx, Slot#4=empty. Both Tx and Rx are 70/140 MHz modules)

N/A WHO?

WHO=aw,bx,cy,dz
(see Description of
Arguments)

Advertising