C.6.7 lnb commands and queries – cdm-qxl only – Mocomtech CDM-QX User Manual

Page 254

Advertising
background image

CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier® Revision

7

Appendix C

MN/CDMQX.IOM

C–36

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

Terminal Tx
Frequency

N/A

10 bytes

Query only.

Terminal Tx Frequency, where frequency = BUC LO

± TFQ

Resolution = 100 Hz

Returns 00000.0000 if BUC LO is zero

Example: TTF=14250.9872

N/A TTF?

TTF=xxxxx.xxxx
(see Description of
Arguments)

C.6.7 LNB Commands and Queries – CDM-QxL ONLY

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

LNB High
Current Limit

LCH=

3 bytes

Command or Query.

LNB higher alarm limit for current, in the form of xxx, where:

xxx is the current value between 50 and 600 mA.

LCH=
LCH?
LCH*
LCH#
LCH^

LCH? LCH=xxx

(see Description of
Arguments)

LNB Low
Current Limit

LCL=

3 bytes

Command or Query.

LNB lower alarm limit for current, in the form xxx, where:

xxx is the current value between 10 and 400 mA.

LCL=
LCL?
LCL*
LCL#
LCL^

LCL? LCL=xxx

(see Description of
Arguments)

LNB Current

N/A

3 bytes

Query only.

Indicates the value of the LNB Current, in the form xxx, where:

xxx is between 0 and 999, units mA.

If not available, response is 000.

Example: LDC=210 (LNB DC current is 210 mA)

N/A LDC?

LDC=xxx
(see Description of
Arguments)

LNB Voltage

N/A

4 bytes

Query only.

Indicates the value of the LNB Voltage, in the form xx.x, where:

xx.x is between 0 and 20.0

If not available, response is 00.0

Example: LDV=18.1 (LNB DC voltage is 18.1 volts)

N/A LDV?

LDV=xx.x
(see Description of
Arguments)

LNB
Frequency
Reference
Enable

LFR=

1 byte, value of
0, 1

Command or Query.

Sets LNB Frequency Reference in the form x, where:

0=Disable LNB Reference
1=Enable LNB Reference

LFR=
LFR?
LFR*
LFR#
LFR^

LFR? LFR=x

(see Description of
Arguments)

Advertising