Mocomtech CDM-QX User Manual

Page 255

Advertising
background image

CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier® Revision

7

Appendix C

MN/CDMQX.IOM

C–37

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

LNB LO
Frequency

LLO=

6 bytes

Command or Query.

LNB Receive LO frequency information in the form xxxxxs, where:

xxxxx is the LO frequency, in the range of 3000 to 65000 MHz.

s is the sign for the mix (+ or – character)

All 0’s (000000) disables this feature.

Terminal Frequency = LNB LO RFQ

Example: LLO=06000- (LO is 6 GHz, high-side mix)

LLO=
LLO?
LLO*
LLO#
LLO^

LLO? LLO=xxxxxs

(see Description of
Arguments)

LNB Power
Control

LPC=

1 byte, value of
0,1,2

Command or Query.

Sets LNB Power Control in the form x, where:

0=Off
1=On, 13V LNB Voltage
2=On, 18V LNB Voltage

Example: LPC=1 (LNB Power is On, 13V)

LPC=
LPC?
LPC*
LPC#
LPC^

LPC? LPC=x

(see Description of
Arguments)

Terminal Rx
Frequency

N/A

10 bytes

Query only.
Terminal Rx Frequency, where frequency = LNB LO

± RFQ

Resolution = 100Hz
Returns 00000.0000 if LNB LO is zero
Example: TRF=11650.2249

N/A TRF?

TRF=xxxxx.xxxx
(see Description of
Arguments)

C.6.8 Built-in BERT Commands and Queries (BER Tester)

Parameter

Type

Command

(Instruction

Code and

Qualifier)

Arguments for

Command or

Response to

Query

Description of Arguments

Response to

Command

Query

(Instruction

Code and

Qualifier)

Response to Query

BERT Config
Pattern state
(applies to
module-by-
module basis)

BCP=

1 byte

Command or Query.

Sets BERT pattern in the form x, where:

0 = space
1 = mark
2 = 1:1
3 = 1:3
4 = 63
5 = 511
6 = 2047 (default)
7 = 2047R (or 2047 Alternate)
8 = Mil 188
9 = 2^15-1
A = 2^20-1
B = 2^23-1

BCP=
BCP?
BCP*
BCP#
BCP$
BCP^

BCP? BCP=x

(see Description of
Arguments)