CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier® Revision

7

Automatic Uplink Power Control (AUPC)

MN/CDMQX.IOM

8–3

CAUTION

MAXIMUM (increase the Tx Output Power to the maximum value permitted by the

parameter MAX RANGE).

(Note: If the local demod loses lock, the modem will automatically move its output power to the
nominal value.)

8.3

Compensation Rate

As with any closed-loop control system, the loop parameters must be chosen to ensure stability at
all times. Several features have been incorporated to ensure that the AUPC system does
overshoot, or oscillate.

• First, the rate at which corrections to the output power can be made is fixed at once every

4 seconds. This takes into account the round trip delay over the satellite link, the time
taken for a power change to be reflected in the remote demodulator’s value of E

b

/N

0

, and

other processing delays in the modems.

• Second, if the comparison of actual and target E

b

/N

0

yields a result that requires a change

in output power, the first correction made will be 80% of the calculated step. This avoids
the possibility of overshoot. Subsequent corrections are made until the difference is less
than 0.5 dB. At this point, the output power is only changed in increments of 0.1 dB, to
avoid ‘hunting’ around the correct set point.

8.4

Monitoring

The remote demodulator’s value of E

b

/N

0

can be monitored at all times, either from the front panel

(MONITOR: AUPC) or via the remote control interface. The resolution of the reading is 0.2 dB.
For all values greater than or equal to 16 dB, the value 16.0 dB will be displayed. As long as
framing is enabled, the value will still be available, regardless of the AUPC mode, or framing mix.

Also displayed is the current value of Tx power increase. If EDMAC framing is enabled, but
AUPC is disabled, this will indicate 0.0 dB. This value is also available via the remote control
interface.


Comtech EF Data strongly cautions against the use of large values of permitted
power level increase under AUPC control. Users should consider using the
absolute minimum range necessary to improve rain-fade margin.