xix

Immunity:

EN 50082 Part 1 - Generic immunity standard, Part 1: Domestic,
commercial and light industrial environment.

Additionally, the CDM-Qx/QxL has been shown to comply with the following standards:

EN 61000-3-2

Harmonic Currents Emission

EN 61000-3-3

Voltage Fluctuations and Flicker

EN 61000-4-2

ESD

Immunity

EN 61000-4-4

EFT Burst Immunity

EN 61000-4-5

Surge

Immunity

EN 61000-4-6

RF Conducted Immunity

EN 61000-4-8

Power frequency Magnetic Field Immunity

EN 61000-4-9

Pulse Magnetic Field Immunity

EN 61000-4-11

Voltage Dips, Interruptions, and Variations Immunity

EN 61000-4-13

Immunity to Harmonics

IMPORTANT

To ensure that the Modem continues to comply with these standards,
observe the following instructions:

• Connections to the transmit and receive IF ports (Type ‘BNC’ female connectors for the

CDM-Qx, Type ‘N’ female connectors for the CDM-QxL) should be made using a good
quality coaxial cable; e.g., RG58/U (50

Ω) or RG59/U (75Ω).

• All 'D' type connectors attached to the rear panel must have back-shells that provide

continuous metallic shielding. Cable with a continuous outer shield (either foil or braid,
or both) must be used, and the shield must be bonded to the back-shell.

• The equipment must be operated with its cover on at all times. If it becomes necessary to

remove the cover, the user should ensure that the cover is correctly re-fitted before
normal operation commences.