3 config: remote ( ethernet – Mocomtech CDM-QX User Manual

Page 77

Advertising
background image

CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier®

Revision 7

Front Panel Operation

MN/CDMQX.IOM

5–11

possible. Press ENTER when done. Note that the asynchronous character format is FIXED
at 8-N-1: 8 data bits, 1 stop bit, no parity.)

5.4.1.3 CONFIG: Remote

Æ Ethernet

Ethernet Config: (◄ ►,ENT)
Gateway Address MAC SNMP

Select Gateway, Address, MAC, or SNMP using the

◄ ►

arrow keys, then press

ENTER

.

CONFIG: Remote

Æ Ethernet Æ Gateway

M&C Ethernet IP Gateway:
192.128.001.001 (◄ ► ▲ ▼,ENT)

Edit the IP Gateway Address for the Ethernet M&C port for this unit by first selecting the digit
to be edited using the

ef

arrow keys, then change the value of the digit to be edited by using

the dc arrow keys. Press ENTER when done.

CONFIG: Remote

Æ Ethernet Æ Address

M&C Ether IP Address/Range:
192.168.001.001/24(◄ ►,▲ ▼,ENT)

Edit the IP Address and Range for the Ethernet M&C port for this unit by first selecting the
digit to be edited using the

ef

arrow keys, then change the value of the digit to be edited by

using the dc arrow keys. Press ENTER when done.

CONFIG: Remote

Æ Ethernet Æ MAC

M&C Port MAC Address:
00-06-B0-00-00-D5

As shown in this example, this read-only window displays the factory program MAC address
for the Ethernet management interface.

CONFIG: Remote

Æ Ethernet Æ SNMP

SNMP: Communities Traps
(◄ ►,ENT)

Select Communities or Traps using the

◄ ►

arrow keys, then press

ENTER

.

CONFIG: Remote

Æ Ethernet Æ SNMP Æ Communities

SNMP Communities:
Read Write (◄ ►,ENT)

Select Read or Write using the

◄ ►

arrow keys, then press

ENTER

.

CONFIG: Remote

Æ Ethernet Æ SNMP Æ Communities Æ Read

Read Community: (◄ ► ▲ ▼,ENT)
public

Advertising