CDM-Qx/QxL Multi-Channel Satellite Modem with DoubleTalk™ Carrier-in-Carrier®

Revision 7

Front Panel Operation

MN/CDMQX.IOM

5–10

5.4.1

CONFIG: Remote

Remote Control Entry: Local
Serial Ethernet (◄ ►,ENT)

Select Local, Serial, or Ethernet using the

◄ ►

arrow keys, then press

ENTER

.

5.4.1.1 CONFIG: Remote

Æ Local

If CONFIG: Remote Æ Local is selected, remote control is disabled, although remote monitoring
is still possible.

5.4.1.2 CONFIG: Remote

Æ Serial

Remote Serial Config:
Interface Baudrate (◄ ►,ENT)

Select Interface or Baudrate using the

◄ ►

arrow keys, then press

ENTER

.

CONFIG: Remote

Æ Serial Æ Interface

M&C Serial Interface: RS232
RS485-2W RS485-4W (◄ ►,ENT

From the Interface submenu, the user is further prompted to enter the bus address. Select
RS232, RS485-2W (2-wire), or RS485-4W (4-wire) using the

◄ ► arrow keys, then press

ENTER

.

CONFIG: Remote

Æ Serial Æ Interface Æ RS232

In RS-232 Mode, Serial Bus
Base Address is fixed @ 0000

Note that the bus base address in RS-232 mode is fixed and cannot be edited.

CONFIG: Remote

Æ Serial Æ Interface Æ RS485(-2W, -4W)

Edit RS-485 Serial Bus Base
Address: 0245 (◄ ►,▲▼,ENT)

If either RS-485 mode is selected, edit the RS-485 bus address of this unit by first
selecting the digit to be edited using the

ef

arrow keys, then change the value of the

digit to be edited by using the dc arrow keys. The valid range of addresses is from 1 to
9999. Press ENTER when done.

CONFIG: Remote

Æ Serial Æ Baudrate

M&C Serial Bus Baud Rate:
19200 Baud (▲ ▼,ENT)

Using the cd arrow keys, edit the baudrate of the remote control bus connected locally to
the M&C computer. Values of 2400, 4800, 9600, 19200, 38400, and 57600 baud are