Replacing the fuses – SATO CL 408e User Manual

Page 108

Advertising
background image

Page 6-8

Section 6. Replacement Procedures

SATO CL408e/CL412e Service Manual

PN 9001078

Rev. B

Replacing the Fuses

6.3.2 Removing and Replacing the Internal Fuse(s)

Required:

T3.15A, 250V Fuse or T1 Amp 250V Fuse

To remove and replace these fuse(s) do the following:

STEP

PROCEDURE

1.

Switch the printer OFF and disconnect the power cable.

2.

Raise the access door and remove (2) screws holding the side cover to

the inside frame. Figs. 6-1

3.

Remove (2) screws holding the side cover to the outside frame. Remove

the cover to expose the electronics.

4.

Refer to Fig. 6-8 and locate the appropriate fuse on the PCB.

5.

Remove and replace the fuse(s) with one of equal rating. Do not use a

fuse with a higher rating.

6.

Replace the cover and replace the screws.

7.

Return the printer to service by reconnecting the power cable.

MAIN PC BOARD

FUSES

Fig. 6-8

Advertising