6 print head balance adjustment – SATO CL 408e User Manual

Page 98

Advertising
background image

Page 5-8

Section 5. Mechanical Adjustments

SATO CL408e/CL412e Service Manual

PN 9001078

Rev. B

5.6 Print Head Balance Adjustment

STEP

PROCEDURE

1.

Load the ribbon and label stock into the printer.

2.

Hold eccentric nut along flats with 10mm box wrench and loosen holding screw.

Fig. 5-7

3.

Adjust eccentric nut by rotating CW or CCW.
Rotating CW increases print density on left side of label. CCW decreases print

density on the right side of label. Note indexing marks on plate. Allowable

range is between 7-11 o'clock.

4.

Tighten screw to secure eccentric nut in place.

5.

Loosen and adjust screw along slot to move indexing pointer for maximum print

quality.

To optimize print quality, perform the following steps to adjust the Print Head Balance

using head pattern as a guide. Proper adjustment is necessary to avoid ribbon wrinkle.

Required Equipment:

• 10mm Open End Wrench

• #2 Pozidrv Screwdriver

Fig. 5-7

LOOSEN SCREW

1/4 TURN

USE 10mm BOX WRENCH

TO ADJUST ECCENTRIC

NUT CW OR CCW AND

TIGHTEN SCREW

INDEXING

MARKS

Advertising
This manual is related to the following products: