Page 9-27

Section 9. Optional Accessories

SATO CL408e/CL412e Service Manual

PN 9001078
Rev.B

Real Time Clock Installation

STEP

PROCEDURE

1.

Refer to Figs. 9-42

Remove the EEPROM chip. CAUTION: Using a screwdriver

to remove EEPROM may cause damage to the PCB. Be

sure to have Prom remover under EEPROM and not

under the socket itself.

2.

Install the Real Time Clock Chip in location vacated by the

EEPROM chip. Carefully align and insert the chip with the mark

spot on the chip (identifying pin1) securely into the chip block

socket using the “U” shaped notch as reference. Be very careful not

to bend any chip legs.

3.

Replace the cover reversing the removal steps.

4.

Reattach and plug in the power cord.

Perform the factory reset procedure to complete the installation of

firmware and Real Time Clock Chip.