background image

Page 4-15

Section 4. Electric Checks and Adjustments

SATO CL408e/CL412e Service Manual

PN 9001078
Rev. B

Ribbon Sensor Voltage Checking

ATTACH THE GROUND

(BLACK) PROBE FROM

THE MULTIMETER TO PIN 4

(GROUND) AND THE

SIGNAL (WHITE) PROBE TO

PIN 3

TO CHECK VOLTAGE RANGE FOR
RIBBON SENSOR, ROTATE CARBON
UNWIND SPINDLE.
LOW VALUE ~/- 1.6V
HIGH VALUE ~/- 4.8V