Section 3. Interface Specifications

SATO CL408e/CL412e Service Manual

PN 9001078

Rev. B

NOTE: The signals on pins 1, 3, 4, 6, 9 and 10 each have an open collector output. These pins normally

measure +.07V maximum when a true condition exists. If a false condition occurs, the voltage will drop to

0V. To achieve a signal level of +5V, you must add a 330 ohm, ¼ W pull-up resistor between the open

collector output pin and Vcc (pin 13) as illustrated. This will provide a signal level of +5V for a true

condition and 0V when a false condition exists. The maximum voltage that can be applied to these pins is

+50V and the maximum current they can sink is 500 milliamps.

Pin 13

Vcc= +5V

330 ohm, 1/4W

Pin 1, 3, 4, 6, 9 or 10

Signal Out

Standard Operation

Start of Print Cycle

End of Print Cycle

Print Start

Input

+5V

0V

Print Repeat

Input

+5V

0V

+5V

0V

+5V

0V

Print End

Type 1

Print End

Type 2

+5V

0V

Print End

Type 3

Print End

Type 4

+5V

0V

20 Milliseconds