Electrical checks & adjustments, Electrical checks and adjustments – SATO CL 408e User Manual

Page 75

Advertising
background image

Page 4-1

SATO CL408e/CL412e Service Manual

PN 9001078
Rev. B

"

Section

Electrical Checks and Adjustments

4.1 Overview

This chapter describes how to check CL408e/CL412e Printers voltage levels and adjust

threshold sensor voltages.

The power supply converts 125 VAC into regulated DC voltages. The printer uses: +5V

and +24V. These DC voltages are not adjustable, however you can measure these DC

voltages at test points located on the PCB. Section 4.2 contains procedures for measuring

DC voltage levels.

You can adjust threshold voltage levels for label sensors. These adjustments are made to

allow for variations in the characteristics of the labels used with the printer. If you cannot

calibrate the label sensor voltage level within the specified voltage range, you should

reposition the label sensor by following the adjustment procedures included in this

section. After completing the label sensor adjustment procedures, perform the label

sensor voltage level adjustment procedure.

You can check or adjust:

Power Supply

Label Sensors

Ribbon Sensor

Pitch Offset

Label Positions

Checks and adjustments in this section require standard metric tools.
Also required:

Digital Multimeter required for use with SATO TP Test Module (Voltage
Checker) Part # RH1773100 and is required for most electrical
adjustments.

Advertising
This manual is related to the following products: