1–1b: midi filter, Rt (realtime command) [off, on, Convert position [premidi, postmidi – KORG MICROX X50 User Manual

Page 89: Local control on [off, on, Enable program change [off, on, Bank (bank change) [off, on, Combi (combi change) [off, on

Advertising
background image

82

RT (Realtime Command)

[Off, On]

Off (unchecked):

MIDI common messages and realtime

messages (Start, Stop, Continue, Song Select, Song Position
Pointer) will not be received if “MIDI Clock” is set to Ext-
MIDI

or Ext-USB, or if it is set to Auto and MIDI clock mes-

sages are being received from an external source. (Song
select messages will be received.)

Use this setting if the X50/microX’s multi set parame-
ters are being unnecessarily reset due to these messages
being received from an external MIDI sequencer.

On (Checked):

The above common messages (including

Song Select) and realtime messages will be received.

This setting is not available if “MIDI Clock” is set to
Internal

.

Convert Position

[PreMIDI, PostMIDI]

This setting specifies the location at which the Transpose,
and will be applied. This setting will affect the MIDI data
that is transmitted and received.
When using this instrument’s keyboard to play the internal
tone generator, the Transpose, and Velocity Curve will
always take effect regardless of this setting.

PreMIDI:

Velocity Curve, and Transpose will be applied to

the data that is transmitted from this instrument’s keyboard.
This setting affects the data that is transmitted from the
MIDI OUT connector or USB connector when you play the
keyboard of the X50/microX. It does not affect the MIDI
data received via MIDI IN.

PostMIDI:

Velocity Curve, and Transpose will be applied to

data before it enters the tone generator. This setting affects
the data that is sent from MIDI IN to the tone generator of
the X50/microX. It does not affect the data that is sent from
the MIDI OUT connector or USB connector when you play
the keyboard of the X50/microX.

Local Control On

[Off, On]

On (checked) Local Control On:

The controller of this

instrument will controls its internal tone generator.
Off (unchecked) Local Control Off:

The controller of this

instrument will be disconnected from the internal tone gen-
erator.
This means that operating this instrument (using the key-
board or controller) will not produce sound.
Uncheck this setting if the echo-back from an external
sequencer causes this instrument to sound in duplicate.

Even if this is unchecked, MIDI transmission and recep-
tion will occur as usual. Note messages will be trans-
mitted when you play the keyboard, and this
instrument’s tone generator will sound when note mes-
sages are received.

1–1b: MIDI Filter

Enable Program Change

[Off, On]

On (checked):

Program changes will be transmitted and

received.
In Program mode (PROG 0: Play), the program will be
switched when a program change message is received on
the global MIDI channel specified by “MIDI Channel” (1–
1a). When you switch programs, a program change message
will be transmitted on the global MIDI channel.

In Combination mode (COMBI 0: Play), the combination
will be switched when a program change message is
received on the global MIDI channel. However, it is possible
to set the “Combi (Combi Change)” parameter so that the
combination is not switched. When a program change is
received on the channel specified for each timbre by “MIDI
Channel” (COMBI 2–1a), the program of that timbre will be
switched. However, the program changes for each timbre
will be affected by the setting of the “Program Change”
parameter (COMBI 3–1a).
When you switch combinations, a program change message
will be transmitted on the global MIDI channel, and also
transmitted simultaneously on the channel of timbres whose
“Status” (COMBI 2–1a) is set to EXT or EX2.

In Multi mode, incoming program change messages on a
channel that corresponds to a track whose “Status” (MULTI
2–1(2)a) is set to INT or BTH will switch programs on that
track. When you select a multi set will be transmitted on the
channels of tracks whose “Status” is set to BTH, EXT, or
EX2

.

Off (unchecked):

Program changes will not be transmitted

or received.

Bank (Bank Change)

[Off, On]

On (checked):

The Bank Select control change message will

be transmitted together with program change messages.
This is valid when “Enable Program Change” is checked.
Off (unchecked):

Bank Select messages will not be transmit-

ted or received.

Combi (Combi Change)

[Off, On]

On (checked):

When in COMBI 0: Play, an incoming pro-

gram change message on the global MIDI channel set by
“MIDI Channel” (1–1a) will switch combinations. This is
valid when “Enable Program Change” is checked. An
incoming program change on a channel other than the glo-
bal MIDI channel will switch the program of any timbre that
matches that MIDI channel.
Off (unchecked):

An incoming program change message on

the global MIDI channel will switch the program of any tim-
bre whose “MIDI Channel” (COMBI 2–1a) matches the glo-
bal MIDI channel. The combination will not be switched.
The program changes for each timbre will be affected by the
setting of the “Program Change” parameter (COMBI 3–1a).

Velocity

Curve

Tone

generator

Note number
change

MIDI IN

MIDI OUT

Transpose

Scale

USB

USB

Velocity

Curve

Tone

generator

MIDI IN

USB

MIDI OUT

USB

Transpose

Scale

Pitch change

MIDI IN
USB

MIDI OUT
USB

Arpeggiator

Local
control

OFF

ON

Trigger

Tone

generator

Advertising