Authentication required:

None: for RIP, there is no need of authentication code.

Password: the RIP is protected by password, authentication code.

MD5: The RIP will be decoded by MD5 than protected by password, authentication code.

Poison Reserve:

Poison Reserve is for the purpose of promptly broadcast or multicast the RIP while the route is

changed. (ex shuting down one of the routers in routing table)

Enable: the gateway will actively broadcast or multicast the information.

Disable: the gateway will not broadcast or multicast the information.



After modifying the RIP parameters, press finish.

The screen will prompt the modified parameter. Check the parameters and perss Restart to restart

the router or press Continue to setup another parameters.