Fitting The Boiler

1. Remove the sealing caps from the boiler connections.

NOTE: A small amount of water may drain from the

boiler once the caps are removed.

2. Lift the boiler as indicated by the shaded areas. The

boiler should be lifted by TWO PEOPLE. Engage the slots

at the top rear of the boiler on the wall plate (Fig. 35)

(see Safe Manual Handling page 5).

3. Insert the sealing washers between the valves and

pipes on the wall plate and the boiler connections. The

rubber washers must be used on the gas connection.

4. Tighten all the connections.

10.5

Fitting the Safety Pressure Relief
Discharge Pipe (Fig. 33)

1. Remove the discharge pipe from the kit.

2. Determine the routing of the discharge pipe in the

vicinity of the boiler. Make up as much of the pipework as

is practical, including the discharge pipe supplied.

3. The pipework must be at least 15mm diameter and

run continuously downwards to a discharge point outside

the building. See section 6.7 for further details.

4. Utilising one of the sealing washers, connect the

discharge pipe to the adaptor and tighten the nut.

5. Complete the discharge pipework and route it to the

outside discharge point.

IMPORTANT: Make all soldered joints before

connecting to the safety pressure relief valve.

Fig. 33

Fig. 32

Pressure Relief Valve

Wall Plate

Discharge Pipe

Suggested Lifting Points

shown as shaded area