17.0

Fault Indication Display

17.0

Fault Indication Display

1. The boiler has three neon indicators. The upper two

function as boiler on and fault indicators.

2. Depending on the nature of the fault the upper two neons

will illuminate, go off or flash.

3. There are five possible combinations, each indicating one

or more fault conditions. These are described below.

A

The flue or flue terminal is blocked or obstructed in some

way, or there is an internal fault.

B

The circulating pump is faulty or the system pressure has

dropped. Check the system pressure. If the pressure is in the

normal range a pump fault is indicated.

C

A fault on the boiler temperature sensor is indicated.

D

The primary system or the boiler has overheated. Allow the

boiler to cool. Turn the selector switch fully anti-clockwise

against the spring pressure to the ‘Reset’ position and hold for

at least 2 seconds.

If the boiler does not relight after resetting it is possible that

the flue has overheated.

E

The burner has failed to light, or incomplete lighting of the

burner has occurred. Turn the selector switch fully anti-

clockwise against the spring pressure to the ‘Reset’ position

and hold for at least 2 seconds.

If the boiler does not relight after resetting blockage of the

condensate drain or trap has occurred.

Burner On

Flame Failure

Power On

Off

Fast Flashing (2 every second)

On

A

Burner On

Flame Failure

Power On

Off

Slow Flashing (1 every 2 seconds)

On

B

Burner On

Flame Failure

Power On

Slow Flashing (1 every 2 seconds)

Slow Flashing (1 every 2 seconds)

On

C

Burner On

Flame Failure

Power On

Slow Flashing (1 every 2 seconds)

On

On

D

Burner On

Flame Failure

Power On

Off

On

On

E