0 changing components – Baxi Potterton Condensing Combination Boiler Performa 24 Eco HE User Manual

Page 42

Advertising
background image

14.0

Changing Components

42

© Baxi Heating UK Ltd 2009

14.14

Pressure Gauge (Figs. 74 & 75)

1. Drain the primary circuit and undo the nut on the

pressure gauge capillary.

2. Remove the timer cover and ease the timer wiring

aside. Undo the screws securing the gauge retaining

bracket.

3. Remove the bracket and gauge assembly. Depress

the barbs on the side of the gauge and remove the

retaining bracket.

4. Reassemble in reverse order.

14.15

Expansion Vessel (Fig. 76)

1. To replace the expansion vessel it is necessary to

remove the boiler from the wall.

Note: Alternatively a vessel of equivalent

capacity can be fitted on the system return

pipe as close as possible to the boiler.

2. Drain the system and undo all gas, water and

condensate drain connections. Remove the flue elbow.

3. Lift the boiler off the wall plate and lay it on it’s side

on a clean flat surface.

4. Undo the nut on the vessel outlet spigot, and

remove the locknut and spring washer securing the

spigot to the boiler chassis.

5. Undo the screws and remove the appliance upper

cross member. Slide the expansion vessel out of the

retaining clips.

6. Reassemble in reverse order. Fully recommission

the appliance and system.

14.16

Condensate Trap (Fig. 77)

1. Disconnect the two sensing wires from the trap

connections.

2. Squeeze together the wire spring clip to release and

ease the inlet pipe from the trap spigot.

3. Undo the nut securing the condensate drain pipe to

the trap. Disconnect the pipe and sealing washer.

4. From underneath the boiler remove the screws

securing the trap bracket.

5. Remove the trap and bracket from the boiler. Undo

the locknut securing the trap to the bracket.

6. Reassemble in reverse order.

Pressure Gauge

Timer Cover

Pressure Gauge

Capillary

Gauge Retaining

Bracket

Expansion Vessel

Retaining Clip

Vessel Outlet Spigot

Boiler Chassis

Lock Nut

Spring

Washer

Fig. 74

Fig. 75

Fig. 76

Inlet Pipe

Sensing Wires

Condensate

Trap

Wire Spring

Clip

Bracket

Condensate

Drain Pipe

Fig. 77