0 changing components – Baxi Potterton Condensing Combination Boiler Performa 24 Eco HE User Manual

Page 41

Advertising
background image

14.0

Changing Components

41

© Baxi Heating UK Ltd 2009

14.11

Pump - Head Only (Fig. 71)

1. Drain the primary circuit and remove the socket

head screws securing the pump head to the body and

draw the head away.

2. Undo the screw on the pump wiring cover and

remove the cover. Using a suitable flat bladed screw

driver press the cable securing levers downwards to

release each wire after noting their position.

3. A standard Grundfos 15-60 replacement head can

now be fitted. Connect the wiring to the new head.

The pump speed must be set to 3 (Fig. 72).

4. Reassemble in reverse order.

14.12

Pump - Complete (Fig. 73)

1. Drain the primary circuit and unscrew the automatic

air vent from the pump body. Undo the two screws

securing the body to the pipe and manifold and draw

the pump forwards.

2. Undo the screw on the pump wiring cover and

remove the cover. Using a suitable flat bladed screw

driver press the cable securing levers downwards to

release each wire after noting their position.

3. Connect the wiring to the new pump. Examine the

‘O’ ring seals on the return pipe and manifold, replacing

if necessary.

4. Fit the air vent to the pump body and reassemble in

reverse order.

14.13

Automatic Air Vent (Fig. 73)

1. Drain the primary circuit and unscrew the automatic

air vent from the pump body.

2. Examine the ‘O’ ring seal, replacing if necessary, and

fit it to the new automatic air vent.

3. Reassemble in reverse order.

Pump Setting

Pump Wiring

Cover

Socket Headed

Screw

Pump Head

Pump Body

Pump Wiring

Cover

Automatic Air

Vent

Fig. 71

Fig. 73

Fig. 72

Advertising